GB10 Cluster Guide DGX Spark and every GB10 workstation

04. Validation: proving the fabric runs at line rate

Summary. Before any model touches the fabric, measure it with RDMA tools, one PCIe half at a time and then both, one pair at a time and then all pairs concurrently. This document is the matrix we ran on six GB10 workstations across two switches: intra-switch pairs, a single cross-switch flow over the 200G inter-switch link, two same-direction flows sharing the ISL, and a bidirectional ISL load with all six nodes busy. The headline results: 196 Gb/s per node through the switch ASIC with both halves active, 109 Gb/s per half through the switch (against 111.86 Gb/s on a direct cable), no measurable ISL penalty for a single cross-switch flow, a fair 82 + 82 Gb/s split when two 100G senders share one ISL direction, and 327 Gb/s aggregate with three concurrent pairs including a bidirectional ISL. It also explains why a single TCP stream is the wrong tool, how to find the right GID index, why a background ib_write_bw server dies with your SSH session, and what the packet_seq_err counter is telling you.

The tools and why

  • ib_write_bw (from the perftest package) drives RDMA writes between two hosts and reports the wire rate. It exercises the same path NCCL uses. It is the authority.
  • iperf3 measures TCP. On the GB10's ARM cores a single TCP stream sits near 12 Gb/s regardless of the link, so a single-stream iperf3 number tells you about the CPU, not the fabric. We report iperf3 only as a sanity check next to the RDMA figure.
  • ping -M do -s 8972 proves MTU 9000 end to end and is the fastest way to spot a detour through a 1500-byte path.
  • NIC counters (ethtool -S, and the RDMA hardware counters under /sys/class/infiniband/<hca>/ports/1/hw_counters/) tell you whether loss is happening.

Health check tool

Everything in this document up to the bandwidth matrix, plus the link, cable, MTU, addressing and NCCL checks from 02-two-and-three-nodes.md, is automated in capetron/gb10-cluster-check (MIT, Python standard library only). It is read-only: every command it runs is a query. Run it on each node before the first ib_write_bw:

git clone https://github.com/capetron/gb10-cluster-check.git
cd gb10-cluster-check
./gb10-cluster-check --peer 198.51.100.2 --peer 203.0.113.2   # one address per half
sudo ./gb10-cluster-check                                     # adds the cable EEPROM check
./gb10-cluster-check --peer 198.51.100.2 --bw                 # after starting the servers there

It verifies, per node: both PCIe halves of each cabled port up at 200G and the count of link drops since boot; the RDMA device behind each interface and its RoCE error counters; the cable module's vendor, part number and length; MTU 9000 on every fabric interface; one subnet per half, no default route via the fabric, and no stale bond or profile still holding a route; the RoCE v2 GID index for each half's address; NCCL_SOCKET_IFNAME, NCCL_IB_HCA and NCCL_IB_GID_INDEX against what it found; and each peer with a small ping and a jumbo do-not-fragment ping. The --bw run uses the ib_write_bw flags below and judges one half against the 109 to 112 Gb/s baseline. Exit code 1 means at least one FAIL, which is the signal to stop and fix before measuring anything.

Finding the RDMA device and GID index

Each QSFP port has two RDMA devices, one per PCIe half (rocep1s0f0 and roceP2p1s0f0 for Port 0). RoCE v2 needs a GID index that maps to the IPv4 address on that half, and GID indices are not stable across nodes or ports. Never hard-code one. Look it up:

hca=rocep1s0f0
for i in /sys/class/infiniband/$hca/ports/1/gids/*; do
  idx=${i##*/}
  echo "$idx $(cat $i) $(cat /sys/class/infiniband/$hca/ports/1/gid_attrs/types/$idx 2>/dev/null)"
done

Pick the entry whose type is RoCE v2 and whose GID ends in the IPv4 address you assigned to that half (the last four bytes of an IPv4-mapped GID are the address). On our units it was index 3 on every half, and the launchers in 05-serving-models.md use NCCL_IB_GID_INDEX=3, but verify on yours.

Running a measurement

Server side (on the receiving node). Run it detached, or it dies with your SSH session and the client reports "Couldn't connect", which looks exactly like a firewall problem and is not:

ssh gb10-02 'sh -c "nohup ib_write_bw -d rocep1s0f0 -x 3 -F -D 6 -s 65536 --report_gbits </dev/null >/tmp/ibw.log 2>&1 &"'

Client side:

ib_write_bw -d rocep1s0f0 -x 3 -F -D 6 -s 65536 --report_gbits 198.51.100.2

Flags: -d RDMA device, -x GID index, -F ignore CPU frequency warnings, -D duration in seconds, -s message size in bytes, --report_gbits print Gb/s. The 65,536 byte, 6 second run is what our six-node matrix used. Our earlier direct-attach runs used -q 8 -s 1048576 -D 10 (eight queue pairs, 1 MiB messages, ten seconds); both give the same wire rate on a healthy link.

For the both-halves number, run two client/server pairs at once, one on rocep1s0f0 against the half-A address and one on roceP2p1s0f0 against the half-B address, and add the two results.

For the concurrent matrix, start every server first, then launch every client in the same second from a script, then collect. A helper that polls for a done marker in the logs must delete the old logs first or it will read the previous run.

Baselines: direct cable

Two units, one 0.5 m QSFP112 DAC, no switch:

Test Result
One half, ib_write_bw 111.86 Gb/s
Both halves concurrently 98.04 + 98.04 = 196.08 Gb/s (98 percent of line rate)
One half on a firmware power-throttled NIC (before OS and firmware update) 12.74 Gb/s

The throttled unit showed 200G, RS-FEC, PCIe Gen5 x4 and a clean mstlink while delivering 12.74 Gb/s. Only this measurement revealed it. Re-run after any rebuild.

Through one switch

Four MSI units on the first switch, measured between the two units on different DD ports so the traffic crosses the switch ASIC rather than staying inside one breakout:

Test Result
Both halves, ib_write_bw, 65,536 B, 6 s 98.0 + 98.0 = 196 Gb/s
iperf3 TCP on both halves 93.1 + 92.6 Gb/s

No PFC, no ECN. Two DGX Spark units on the second switch, one half:

Test Result
ib_write_bw through switch B 109.11 Gb/s (direct-attach baseline 111.86)
Jumbo ping both planes clean

The switch costs about 0.75 Gb/s per half, 0.7 percent. That is the whole penalty.

The six-node matrix (all six concurrent where stated)

All runs: ib_write_bw, 65,536 byte messages, --report_gbits, one half per pair. Pairs are listed as client to server. A four-node tensor-parallel serving run was live on the first switch's units throughout and survived every round.

Round Pairs Result, Gb/s
R1, intra-switch, three pairs gb10-01 to gb10-02; gb10-03 to gb10-04; gb10-05 to gb10-06 109.31 + 109.22 + 109.27 = 327.8 aggregate
R2a, one cross-switch flow over the ISL gb10-05 to gb10-01 109.08 (no measurable ISL penalty)
R2b, two cross-switch flows in the same direction, plus one intra gb10-05 to gb10-01; gb10-06 to gb10-02; gb10-03 to gb10-04 81.92 + 81.90 (163.8 on the 200G ISL, fair split) + 109.13 intra
R3, bidirectional ISL, plus one intra gb10-05 to gb10-01; gb10-02 to gb10-06; gb10-03 to gb10-04 109.19 + 109.10 + 109.14 = 327.4 aggregate

Reading the rows:

  • R1 says the two pods are indistinguishable. A DGX Spark pair and an MSI pair land within 0.1 Gb/s of each other.
  • R2a says the ISL costs nothing for one flow. 109.08 through two switches and a 200G DAC versus 109.31 through one switch.
  • R2b is the only oversubscribed case: two 100G senders into one 200G ISL direction is 200 into 200 with no headroom, and each half only ever delivers about 109. The ISL split them almost perfectly evenly at 81.9 each, 163.8 total, with no PFC configured. DCQCN (the RoCE congestion control in the NIC, driven by ECN marks and congestion notification packets) handled it. This is also the only round where packet_seq_err grew, by about 5,500 over the run.
  • R3 says the ISL is full duplex. One flow in each direction plus an intra-switch pair gives the same 327 Gb/s aggregate as three intra-switch pairs.

Before the RSTP fix in 03-switched-fabric.md, the R2a path measured 4.47 Gb/s. We first attributed it to contention (the four MSI units were loading a model at the time), and the idle re-test above shows the real path. If you see a cross-switch number in the single digits, check the ISL's RSTP role before checking anything else.

What packet_seq_err means

packet_seq_err is a ConnectX hardware counter (under the RDMA device's hw_counters) that increments when the NIC receives a RoCE packet whose packet sequence number is not the one it expected. On a lossless-by-assumption RDMA transport that means a packet was lost or reordered in flight and the responder is asking for a retransmit. Two very different situations produce it:

  1. Oversubscription with congestion control working. R2b above: two 100G senders into one 200G direction. The switch marks or drops under pressure, the NICs send congestion notification packets, DCQCN backs the senders off, and the counter grows by a few thousand while throughput settles at a fair split. Throughput is fine. The counter is telling you the ISL is at capacity, which you already knew.
  2. A path that is dropping most of what it is given. The second-bridge trap in 03-switched-fabric.md: the switch CPU could forward a few Gb/s and dropped the rest. The counter grew, CNPs flew, and throughput collapsed from 196 to under 5 Gb/s. The counter is telling you the path is broken.

Tell them apart by throughput: if ib_write_bw reports near line rate, the errors are congestion feedback and DCQCN is doing its job; if it reports single digits with the same counter growing, something in the path is software-forwarding, mis-negotiated, or running at MTU 1500. Under no circumstances does a healthy, unloaded pair grow this counter; R1, R2a and R3 grew it by zero.

If you run many cross-switch senders routinely, PFC and ECN on the ISL are the next knobs. We have not needed them.

Confirming the model is actually using the fabric

After a serving run, read the byte counters on the RDMA device and compare to before. During a four-node GLM-5.3-Flash run, 17 GB crossed rocep1s0f0 on the head node; during a two-node Qwen3.8-Flash-Next run, 11 GB. If the counter did not move, NCCL fell back to sockets over the management network and every result you collected is a management-LAN result (see the 539 versus 1,963 tok/s comparison in 02-two-and-three-nodes.md).

Sources

  • Our measurement logs: 2026-08-15 (direct-attach 111.86 and 196.08 Gb/s, 12.74 Gb/s throttle, -q 8 -s 1048576 -D 10 flags, GID index lookup path, single-stream TCP near 12 Gb/s), 2026-08-28 (196 Gb/s through the switch ASIC, iperf3 93.1 + 92.6, 65,536 B / 6 s flags, 17 GB and 11 GB RDMA byte counts), 2026-08-31 (109.11 DGX Spark pair, six-node matrix R1 to R3, packet_seq_err growth of about 5,500 in R2b, 4.47 Gb/s before the RSTP fix, second-bridge collapse to 4.85 / 4.9 / 8.8 Gb/s, detached ib_write_bw server gotcha)
  • perftest (ib_write_bw) documentation for flag meanings: https://github.com/linux-rdma/perftest
  • NVIDIA DGX Spark User Guide, ConnectX-7 Networking (RDMA device names): https://docs.nvidia.com/dgx/dgx-spark/spark-clustering.html