02. Two nodes and three nodes: the switchless configurations

Summary. NVIDIA supports two switchless topologies for GB10 workstations: two units joined by one QSFP cable, and three units joined by three cables in a ring, each unit using both of its QSFP ports. Both are covered by official NVIDIA playbooks and both are what the cluster cable was made for. Three is the switchless ceiling because each unit has exactly two ports; a fourth unit needs a switch (see 03-switched-fabric.md). This document covers the physical connection, addressing that survives reboots, jumbo frames, how to prove the link is healthy before you start a model, and why bonding the two PCIe halves of a port does not do what people expect.

Two units: one cable

NVIDIA's "Connect Two Sparks" playbook describes "high-speed inter-node communication using 200GbE direct QSFP connections" with one QSFP cable. Prerequisites from the playbook: two systems, SSH access to both, root or sudo on both, the same username on both, key-based SSH between them with no interactive prompt. NVIDIA rates it at one hour including validation, medium risk, and reversible by removing the netplan configuration. NVIDIA also ships a discover-sparks.sh script for node discovery and SSH key distribution, and a Sync Cluster Assistant that does discovery, validation and SSH setup automatically.

Physically: one cable from Port 0 on the first unit to Port 0 on the second. Port 0 is the left QSFP port, nearest the RJ45 jack. Which port you pick does not matter for bandwidth; it matters for consistency in the interface names below.

What you get from one cable: one 200 Gb/s link made of two 100 Gb/s PCIe halves. Every procedure below configures both halves. If you configure only enp1s0f0np0 you will measure about 111 Gb/s and wonder where the other half went.

Cable: https://petronellatech.com/hardware/dgx-spark-cluster-cable/

Three units: a ring of three cables

NVIDIA's "Connect Three DGX Spark in a Ring Topology" playbook uses "three QSFP cables for direct 200GbE connection" between three systems. Each unit uses both of its QSFP ports, and every cable joins a Port 0 to a Port 1, exactly as the playbook wires it:

Cable From To
1 Node 1, Port 0 Node 2, Port 1
2 Node 2, Port 0 Node 3, Port 1
3 Node 3, Port 0 Node 1, Port 1

Port 0 is the QSFP cage next to the RJ45 jack; Port 1 is the one further away. The mapping matters because the playbook's netplan files put the matching subnet on each Port 0 / Port 1 pair. Wire Port 0 to Port 0 and every interface still shows link up, but the two ends of that cable sit in different subnets and ping fails. Every unit has a direct link to every other unit, so this is a full mesh, not a bus. Prerequisites match the two-node playbook plus current OS and firmware on all three.

This is the switchless ceiling. With two ports per unit, a fourth unit cannot reach every other unit directly; you can wire four units as four point-to-point links, but then two of the units have no direct path to each other. We built exactly that with four units and /30 links before we bought the switch and confirmed there was no route between the two non-adjacent units. All-to-all over four needs three links per node, and the hardware has two. Four or more means a switch.

Three cables: https://petronellatech.com/blog/dgx-spark-cluster-cables-in-stock-0-5m-qsfp112-400g-dac-for-every-gb10-workstation-159-shipped/

Addressing

Two schemes work. Both use the same rule: one subnet per PCIe half, and never a default route on the fabric interfaces.

Point-to-point /30s (two nodes, or the three-node ring)

Give each cable its own /30 for the first half and a second /30 for the second half. The scheme we used put the second half ten higher in the third octet, so it is obvious at a glance which half you are looking at:

Link First half (enp1s0fXnpX) Second half (enP2p1s0fXnpX)
gb10-01 to gb10-02 198.51.100.0/30 203.0.113.0/30
gb10-01 to gb10-03 198.51.100.4/30 203.0.113.4/30
gb10-02 to gb10-03 198.51.100.8/30 203.0.113.8/30

(198.51.100.0/24 and 203.0.113.0/24 are RFC 5737 documentation ranges; substitute your own private ranges.)

Flat planes (what we moved to for the switch, and what we would use again for three)

One /24 per half, one host number per unit. Half A of every unit is 198.51.100.N/24, half B is 203.0.113.N/24, and N is the unit number. This is the scheme we run on the switched fabric and it is simpler to reason about than /30s even without a switch; it also means the addressing does not change when you add the switch later.

Making it persist

This is where most of our early time went. Fabric addresses that live only in a running kernel do not survive a reboot, and a unit that reboots into the wrong address on the wrong link is the third most common fault we hit. Two mechanisms, depending on the vendor:

DGX Spark Founders Edition (netplan, systemd-networkd). Drop a file such as /etc/netplan/40-cx7.yaml:

network:
  version: 2
  renderer: networkd
  ethernets:
    enp1s0f0np0:
      addresses: [198.51.100.5/24]
      mtu: 9000
      link-local: []
      dhcp4: false
      dhcp6: false
    enP2p1s0f0np0:
      addresses: [203.0.113.5/24]
      mtu: 9000
      link-local: []
      dhcp4: false
      dhcp6: false

netplan apply did not drop our management SSH session. Remove any older netplan fragments that still assign the old direct-attach addresses to the same interfaces, and back the directory up first. On the DGX Spark the fabric NICs show as unmanaged in NetworkManager, which is correct: networkd owns them.

MSI EdgeXpert (NetworkManager). One profile per half, IPv6 off, never a default route, MTU 9000:

nmcli con add type ethernet ifname enp1s0f0np0 con-name fabric-a \
  ipv4.method manual ipv4.addresses 198.51.100.1/24 ipv4.never-default yes \
  ipv6.method disabled 802-3-ethernet.mtu 9000
nmcli con add type ethernet ifname enP2p1s0f0np0 con-name fabric-b \
  ipv4.method manual ipv4.addresses 203.0.113.1/24 ipv4.never-default yes \
  ipv6.method disabled 802-3-ethernet.mtu 9000

Then the trap that cost us a launch: an old profile that is carrier-down can still hold an address and still own a route. When we retired a direct-attach bond, the bond interface with no carrier kept its old /30 and the kernel routed the first four addresses of the new /24 into it. Ping to the fifth address worked; ping to the second and third failed. nmcli con down <old-profile> fixed it; setting the old profiles to autoconnect no keeps it fixed. Audit with ip route after every change; every fabric route should point at a fabric interface with carrier.

MTU 9000

Set mtu 9000 on every fabric interface on every unit. There is no negotiation to save you: a 1500-byte interface on one end of a 9000-byte link silently fragments or drops large frames and NCCL bootstraps then stalls. Verify with a jumbo ping that forbids fragmentation:

ping -M do -s 8972 -c 3 198.51.100.2

8972 is 9000 minus the 20-byte IP header and 8-byte ICMP header. A clean reply from every unit on both planes means MTU is right end to end. When a unit later joins a switch, the same ping proves the switch path too (see 03-switched-fabric.md for the switch-side l2mtu that must also be set).

Run these in order. Each one rules out a class of fault the next one would misreport.

  1. Link state and speed. On each unit, ethtool enp1s0f0np0 | grep -E 'Speed|Link' should show 200000Mb/s and Link detected: yes on both halves. This proves the cable and the NIC negotiated. It does not prove throughput (see item 4).
  2. Addresses and routes. ip -br addr show enp1s0f0np0 enP2p1s0f0np0 and ip route. Two addresses, two routes, no default route on either, no stale routes into interfaces without carrier.
  3. Jumbo ping on both planes, as above.
  4. RDMA bandwidth, one half at a time, then both. This is the only test that catches a power-throttled NIC or a CPU-forwarded path. Full commands and expected numbers are in 04-validation.md. Expect about 111 Gb/s per half on a direct cable and about 196 Gb/s with both halves running concurrently. If a half reads 12 to 13 Gb/s with everything else green, update the OS and firmware and reboot before doing anything else.
  5. Peer firewall. If a host firewall is on, multi-node vLLM needs full peer connectivity, not just the rendezvous port: the collective bootstrap opens dynamic ports and the head node also connects to its own address. Allow both fabric subnets from every peer, including the unit itself.
  6. Same container image digest everywhere. Two units pulling "the same" nightly tag on different days got different NCCL builds, and the symptom was a bootstrap warning about a message truncated by four bytes that looked exactly like a network fault. Pin the digest.

What a bond does not give you

People bond the two halves of a port because two interfaces on one wire look like a classic active-active pair. Three things to know before you do:

  1. RDMA bypasses the bond. NCCL and ib_write_bw talk to the RDMA devices (rocep1s0f0, roceP2p1s0f0), not to the bonded Ethernet interface. NCCL uses both halves on its own when you list both in NCCL_IB_HCA. A bond adds nothing to the path that carries the model's traffic.
  2. TCP does not fill even one half. A single TCP stream on the GB10's ARM cores sits near 12 Gb/s. Bonding two halves does not make one stream faster; at best it lets many streams spread. If you need TCP throughput for weight distribution, use many parallel streams (we fan out weights with tar | ssh at about 830 MB/s over the fabric, which is a single stream with a large block size and works well enough).
  3. The bond is the thing that keeps stale state. Our carrier-down bond holding an old address and a live route (above) is the direct consequence of having a bond at all. Two plain interfaces with two plain addresses have no such failure mode.

The one place the second half matters for plain IP is NCCL's socket bootstrap, which uses one Ethernet interface (NCCL_SOCKET_IFNAME=enp1s0f0np0). It only needs to exist and route; it does not need to be fast.

What sharding over the wrong network costs

We measured this once so you do not have to. The same dense 27B FP8 model, same pinned image, same flags:

Configuration Prefill Decode
1 unit, tensor parallel 1 1,963 tok/s 8.3 tok/s
4 units, tensor parallel 4, over 10 Gb/s Ethernet 539 tok/s 3.5 tok/s

Three extra units over the management LAN made prefill 3.6x slower and decode 2.4x slower. Tensor parallel is only worth running over the RDMA fabric at line rate, and only for models whose per-rank working set shrinks enough to pay for the collectives. The four-node results that do work are in 05-serving-models.md.